黃浦倍福伺服驅動器維修:F73F, Feedback "general": Feedback id has been incorrectly parametrized反饋“常規”:反饋id參數設置錯誤。
The internal ID parametrized in the feedback system does not correspond to the ID entered in the IDN "P-0-0150" or "P-0-0180".反饋系統中參數化的內部ID與IDN“P-0-0150”或“P-0-0180”中輸入的ID不一致。
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
診斷代碼(十六進制)診斷代碼(Dez)
F73F 63295
Class Type
類別類型
Error Parameter error
參數錯誤
Standard Reaction Reset
標準反應復位
The power stage is already switched off Execute Reset-Command (S-0-0099).
電源級已關閉執行復位命令(S-0-0099)。
Possible Causes Solutions
可能的原因解決方案
You have selected an incorrect feedback system. Compare the selected feedback system with the actually existing one.
您選擇的反饋系統不正確。將選定的反饋系統與實際存在的反饋系統進行比較。
The feedback database was incorrectly parametrized. Call our support dept. and replace the feedback database.
反饋數據庫的參數設置不正確。致電我們的支持部門并更換反饋數據庫。
During the motor replacement a motor with different feedback was connected.
在更換電機期間,連接了一個具有不同反饋的電機。
Please correct the feedback-parameterization.
請更正反饋參數化。
Further Information AX5000_IDN-Description: "P-0-0150-->Parameter channel-->Identifier" or "P-0-0180-->Parameter channel-->Identifier。進一步信息AX5000_IDN-說明:“P-0-0150-->參數通道-->標識符”或“P-0-0180-->參數通道->標識符。